eMod005 / Adaptronic Modular plug-in ECU - S13,S14a,S15 Nissan 64-pin

Uitverkocht
€ 1.171,88

This product is one of Adaptonic’s plug-in ECUs, also called eMod005. It’s a direct plug and play for the Nissan Silvia S13, S14 (64-pins), S15.

Our main objective in creating the Adaptronic Modular ECU line is to work towards Adaptronic’s mission which is to give people control. In doing this, we came up with a system which would give people greater flexibility and at the same time, overcome the limitations of our main product line, the Select ECUs.

 

What's in the box?

  • Engine control unit
  • USB (tuning) cable
  • Vacuum hose
  • 1GB USB Stick
  • Key ring
  • Adaptronic stickers

 

General Features

 

  • Modular system, so that people can buy hardware upgrades later as their needs develop (eg additional inputs, outputs, or specific functions, eg drive by wire or built-in lambda)
  • Wireless communication
  • Fast USB communication, requiring no drivers
  • Headphone port for listening to the knock sensor while tuning
  • 4 x serial ports
  • 1 x CAN port
  • Power over USB to do loading of maps, firmware etc without having to provide it with 12V power
  • 32MB of onboard logging to flash
  • Exception logging, able to detect faults and log a bunch of things that happen around the same time to help with ECU setup and tech support
  • Bigger maps, more of them, and more dedicated maps.
  • Tested to MIL-STD-202G, a military vibration standard, which varies the frequency and peaks at 7.5g of oscillating acceleration

Features / Specifications

 

Variable

Number

Details

Analogue 0-5V inputs 10

Each is 0 – 5.5V, 55k input impedance

 

  • 2 x TPS / pedal position
  • 6 x pressure – Oil, Fuel, Internal intake MAP, internal exhaust MAP, external intake MAP, external exhaust MAP
  • 2 x spare for servo feedback / external inputs

Analogue oxygen sensor input 1

Each can be either:

 

  • 0 – 5.5V, 55k input impedance
  • 0- 3.3V, 1M input impedance

Temperature inputs 4

Each is 0 – 5.5V, 55k input impedance to ground
Each can be:

 

  • Non-biased, eg in piggyback mode. Calibration is in mV
  • Biased, calibration is in Ohms. 3 internal pull-ups, 1k5, 2k2, 4k7, automatically selected by the ECU

Manifold air temperature, coolant temperature, oil temperature, fuel temperature

Crank trigger inputs 3

  • Selectable 2k2 pullup (on in digital mode, off in reluctor mode)
  • Variable voltage trigger threshold from 0 to 65V – either arm input for reluctor or threshold for digital input
  • AC coupled zero crossing trigger in reluctor mode
  • Variable filtering 1 to 192 µs
  • See built-in scope section

Vehicle speed input 1

  • Selectable 2k2 pullup
  • Variable voltage trigger threshold from 0 to 65V
  • Variable filtering 1 to 192 µs
  • See built-in scope section

Sensor power and ground

  • 5V regulated output for sensors, max 100 mA, current limited (voltage is monitored by ECU)
  • Sensor ground connected to ground inside ECU under firmware control to detect external ground loops in the wiring (voltage is monitored by ECU)

Knock input 1

  • 50 k input impedance
  • Sampled at 80 kHz (12-bit resolution, 3.3V peak to peak max voltage),
  • Variable second order highpass and lowpass filters
  • Selectable start and end of sampling windows (in crank angle)

Wired Outputs 2

  • Dedicated outputs for tacho and EFI relay
  • Tacho output has inductor to generate back-EMF spike for impulse tachometers.
  • EFI relay output can be configured as fuel pump or EFI relay. Switches to ground, current limited to 600 mA

Headphone output 1

Mono output, can be selected as direct knock input or filtered knock input

Power sources 3

ECU can be powered by 12V EFI input, ignition switch, or USB (USB for settings / firmware upgrades / log retrieval only; 12V must be applied to read inputs)

CAN channel 1

  • Up to 1 Mbps
  • Internal 120 Ohm terminating resistor can be turned on and off with ECU setting on each channel

USB connection 1

  • Standard USB mini AB connector.
  • 12 Mbps max speed
  • USB appears as mass storage device (USB stick); no drivers are necessary
  • Software installer included on mass storage device

Serial connections 4

  • All 4 use 4-pin Molex connectors
  • 2 x serial in (ground, transmit, receive)
  • 1 x serial out (ground, transmit, receive)
  • 1 x controller out (ground, transmit, receive and 12V switched, current limited power) – eg for dash, hand controller

Wireless connection 1

  • Access point
  • 230kbps max speed
  • Settings and live data only (no log retrieval due to speed)

Inbuilt sensors

  • Microphone
  • 3 axis accelerometer
  • 3 axis rate gyro

Inbuilt logging 32 MB

  • Max 30 hrs @ 10 Hz, 13 channels
  • Min 20 mins @ 100 Hz, 125 channels

Exception (fault) detection 16 MB

Separate logging memory for storing logs during “exceptions” (sensor / trigger faults etc)

Built-in scope

4 channels

  • Max sample rate 200 kHz (5µs sample period)
  • 1000 samples per screen (min 5ms across the screen)
  • Analogue trigger inputs sampled at 40 kHz

Channels include

  • Analogue CAS inputs
  • Peak detected CAS voltages
  • CAS threshold voltages
  • Filtered CAS inputs
  • Analogue external inputs
  • Raw and filtered knock waveforms
  • Current engine angle
  • Calibrated input values
  • Intermediate calculation values
  • Output calculated values

Main loop execution speed

Variable depending on tuning mode and corrections enabled, 400 Hz nominal

 

Number of injector outputs 8

  • Switching topology for low heating
  • Peak and hold current waveforms
  • Programmable peak and hold current
  • Max current per channel 4A continuous
  • Nominal current per channel 1A (can be controlled in software)
  • Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground
  • Output voltage and current monitored

Number of ignition outputs 8

  • Appears as a 470 Ohm to supply when high, short to ground when low
  • Current limited output
  • Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground, and only low current
  • Voltage and current monitored

Number of aux outputs 4

  • Push-pull outputs (can drive high or low)
  • High side current limited to 1.2A
  • Low side current up to 4A continuous
  • Can be PWM but not engine synchronous
  • Voltage and current monitored

Hardware upgrade 1

  • Small Modules ( analogue input, real – time input, drive – by – wire control and output module)